An experimental study on a bus air conditioner to determine its conformty to design and comfort condition

Yükleniyor...
Küçük Resim

Tarih

Yazarlar

Ünal, Şaban

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Yildiz Technical University Press

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

The air conditioning system for a bus should be selected considering a number of parameters, including passenger capacity, local climatic conditions, and fuel consumption. It is possible to determine whether a selected air conditioning system provides desired performance through testing. This study examines how to verify experimentally whether a bus air conditioning system meets design and comfort requirements. An experimental study was conducted on a prototype bus and was tested when driving on the Adana-Ceyhan highway in Turkey. The internal and external temperatures, evaporator inlet and outlet temperatures and relative humidity values were measured. Thermal sensation values were calculated by using empirical correlations given by ASHRAE. Furthermore, the instantaneous cooling load of the bus was obtained according to the experimental data, and the results are compared with the calculated cooling load of the bus by using the radiant time series method provided by ASHRAE. With respect to the obtained results, the selected air conditioning system conformed to design and comfortrequirements.

Açıklama

Anahtar Kelimeler

Bus air-conditioning, Cooling load, Thermal sensation, Comfort conditions

Kaynak

Journal of Thermal Engineering

WoS Q Değeri

Scopus Q Değeri

Cilt

3

Sayı

1

Künye

Ünal, Ş. (2017). An experimental study on a bus air conditioner to determine its conformty to design and comfort condition. Journal of Thermal Engineering, 3(1), 1089-1101

Onay

İnceleme

Ekleyen

Referans Veren