In this study, calorimetric method is used to derive the depth doses calculation. In the experiment at the KeV level, an Ir-192 source with three different gamma energies was used. The source activity is approximately 9.15 curie. The Ir-192 radioactive source is mainly used for industrial purposes. This study had been made to determine organ dose values in any industrial accident. The data are calculated as surface dose and depth dose. Values for different time intervals have been measured. Time and depth parameters for measurements and calculations were obtained for 30 different values. The results of the experiment and the calculations have been compared.

Açıklama

Anahtar Kelimeler

Kaynak

3rd international conference on theoretical and experimental studies in nuclear applications and technology (TESNAT)

WoS Q Değeri

Scopus Q Değeri

Cilt

154

Sayı

Künye

Ugur, F. A., Goren, E., (2017). Depth dose calculations. Aydin, A., Sarpun, I. H., Tel, E., Kaplan, A., Demir, B., (ed.).3rd International Conference on Theoretical and Experimental Studies in Nuclear Applications and Technology (TESNAT). 154(Article Number: 01023). DOI: 10.1051/epjconf/201715401023