Exergy analysis of a novel configuration of desiccant based evaporative air conditioning system

dc.authoridHURDOGAN, ERTAC/0000-0003-1054-9964;
dc.contributor.authorUckan, Irfan
dc.contributor.authorYılmaz, Tuncay
dc.contributor.authorHurdogan, Ertac
dc.contributor.authorBuyukalaca, Orhan
dc.date.accessioned2025-08-12T08:26:46Z
dc.date.issued2014
dc.departmentOsmaniye Korkut Ata Üniversitesi
dc.description.abstractIn this work, a process is developed for exergy analyses of a novel configuration of desiccant based an evaporative air conditioning system. The exergy transfer and destruction between the components of the system are defined for the average measured variables obtained from the experimental results. The exergy formulations are carried out to the experimental system using the data collected during a typical operation of the system. The exergy output, specific flow exergy, exergy destruction, exergy input and exergy efficiency are determined. Furthermore, the sustainability assessment and relative irreversibility of components are obtained. It is found that the exergy efficiency of the entire experimental unit is 40.7% at a reference temperature of 15 degrees C. It is also observed that the exergy efficiencies of the entire system varies between 56% and 25% for reference temperature of 0-30 degrees C, respectively. The effects of reference temperature on the performance of the studied system are investigated. Based on the investigation, it is seen that an exergy analysis can provide beneficial knowledge with respect to the theoretical upper limit of the system performance. (C) 2014 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.enconman.2014.05.006
dc.identifier.endpage532
dc.identifier.issn0196-8904
dc.identifier.issn1879-2227
dc.identifier.scopus2-s2.0-84901001862
dc.identifier.scopusqualityQ1
dc.identifier.startpage524
dc.identifier.urihttps://doi.org/10.1016/j.enconman.2014.05.006
dc.identifier.urihttps://hdl.handle.net/20.500.12502/5136
dc.identifier.volume84
dc.identifier.wosWOS:000338601100053
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy Conversion and Management
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250812
dc.subjectExergy analysis
dc.subjectDehumidification
dc.subjectEvaporative cooling
dc.subjectDesiccant
dc.subjectAir conditioning
dc.titleExergy analysis of a novel configuration of desiccant based evaporative air conditioning system
dc.typeArticle

Dosyalar