Thermodynamic analysis of a refrigeration system with double evaporators and ejector

dc.authorid0000-0002-4276-2412
dc.authorid0000-0002-8462-0420
dc.contributor.authorÜnal, Şaban
dc.contributor.authorErdinç, Mehmet Tahir
dc.contributor.authorKutlu, Çağrı
dc.date.accessioned2021-09-22T07:31:07Z
dc.date.available2021-09-22T07:31:07Z
dc.date.issued2016tr
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractIn this study, theoretical investigations of double evaporator refrigeration system and with adding an ejector to the current system were carried out using energy and momentum equations. The relative increase in COP with respect to the conventional double evaporator refrigeration system was analyzed in terms of condenser and evaporator temperatures. Also exergy analyses of systems were examined and results were showed graphically. In the study, R134a and its potential substitute R1234yf were used. The analyses showed that COP improvements of the proposed system by using ejector as an expansion device were approximately 15% for R134a and about 17% for R1234yf, respectively.tr
dc.identifier.citationUnal, S., Erdinc, M. T., Kutlu, C., (2016). Thermodynamic analysis of a refrigeration system with double evaporators and ejector. Journal of Faculty of Engineering And Architecture Of Gazi University. 31(4), 1039-1047. DOI: 10.17341/gazimmfd.278459tr
dc.identifier.doi10.17341/gazimmfd.278459
dc.identifier.endpage1047tr
dc.identifier.issue4tr
dc.identifier.scopusqualityQ2
dc.identifier.startpage1039tr
dc.identifier.urihttps://doi.org/10.17341/gazimmfd.278459
dc.identifier.urihttps://hdl.handle.net/20.500.12502/572
dc.identifier.volume31tr
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherGAZI UNIV,tr
dc.relation.ispartofJournal of Faculty of Engineering And Architecture Of Gazi University
dc.relation.publicationcategoryUlusal Hakemli Dergide Makale - Kurum Öğretim Elemanıtr
dc.rightsinfo:eu-repo/semantics/openAccesstr
dc.subjectEjectortr
dc.subjectDouble evaporatortr
dc.subjectCooling effecttr
dc.subjectR1234yftr
dc.subjectExergy analysistr
dc.titleThermodynamic analysis of a refrigeration system with double evaporators and ejectortr
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Unal, Saban.4.pdf
Boyut:
1.35 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Fulltext/Tam Metin

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: